CHiNT Electric

CHINT – Leading Brand in Switchgear
CHINT group provides safe, reliable, and stable industrial electrical equipment’s and solutions for energy efficient management systems.With 35 years of development, CHINT has grown to be Asia’s largest low-voltage electrical product supplier and is the leading brand of the whole industry chain in industrial electric in Asia.CHINT has developed business network in over 140 countries and regions with more than 30,000 employees.CHINT has 18 professional technology research institutes and 3 overseas R&D centers. CHINT has won more than 4,000 patent licenses and 5,000 patent applications.
Chint Catalogue / Pricelist
- Contactors & Relay
- Motor Protection & Miniature Relay
- MCB
- MCCB
- Fuse Switch Disconnector
- ATS
- ACB
- VFD & Starter
- Other Products
Mini Contactor

- The NC6 Series Mini Contactor is used in remote motor (≤4kW) control application.
- Rating up to 690V, 9A (AC-3). —– (06A, 09A)
- Standard: IEC/EN 60947-4-1
- Two kinds of mounting available: Normal type (without pins); Pin type (with pins)
- Ambient temp: -5℃~+40℃
- Coil voltage (AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V, 380V, 400V;
- Auxiliary contacts: NCF6-20 & NCF6-02 (2NO or 2NC)
- NCF6-13 & NCF6-31 (1NO & 3NC or 3NO & 1NC)
- NCF6-40 & NCF6-04 (4NO or 4NC)
- Assemble with Thermal Overload Relay NR2-11.5 to be a DOL Starter
The NXRC series contactor relay is used in relay control, signal transmission and isolation amplifier application
- Standard: IEC/EN 60947-5-1
- Ambient temp.: -35℃~+70℃
- Rating up to 690V, Ith=10A
Top mounting auxiliary contacts:
- Contact combination: 4NO or 3NO&1NC or 2NO&2NC or 1NO&3NC or 4NC
Coil Voltage:
- AC: 24V, 36V, 48V, 110V, 127V, 220V, 380V, 415V (AC)
- DC: 24V, 48V, 110V, 220V (DC)
NC1 Contactor and Overload Relay
- The NC1 Series Contactor is used in remote motor (≤45kW) control application.
- Rating up to 690V, 95A (AC-3). —– (09A, 12A, 18A, 25A, 32A, 40A, 50A, 65A, 80A, 95A)
- Standard: IEC/EN 60947-4-1
- Ambient temp: -25℃~+55℃
- Coil voltage (AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V,
- 380V, 415V, 440V, 480V, 500V, 600V, 660V
- Coil voltage (DC): 24V, 36V, 48V, 110V, 220;
- Side & Top mounting auxiliary contacts
- Top mounting time delay block: F5-T (making time delay); F5-D (breaking time delay)
- Assemble with Thermal Overload Relay NR2 (or NRE8) to be a DOL Starter.
- Assemble with another one & F4 & F5 & NR2 (or NRE8) to be a Star-Delta Starter Type QJX2;
- Assemble with a current limiting block to be a Capacitor Contactor.
- Assemble with another one to be a reversing contactor.
Used for long-distance circuit making and breaking
- Rated working voltage up to 690V, 25A and 40A (AC-3)
- w/ 2 NO 2 NC main contacts
- Compliance standards: IEC / EN 60947-4-1
- Ambient air temperature: -25℃~+55℃,
- Coil voltage: DC 48V
- Can form into reversible contactor with other AC contactors
NR2 series thermal overload relay is used to provide overload and phase failure protection for AC motors.
- Contacts: 1N0+1NC (Electrical separated / Potential Free)
- Test / Hand & Self Reset
- Rating up to 690V, 630A. —– (11.5A, 25A, 36A, 93A, 150A, 200A, 630A)
- Standard: IEC/EN 60947-4-1
- Ambient temp: -5℃~+40℃
- NR2 Assemble with Contactor NC1, NC2, NC7 to be a DOL Starter.


NC2 Contactor and Overload Relay


- Rating up to 690V, 800A (AC-3) —– (115A,150A,185A,225A,265A,330A,400A,500A,630A,800A)
- Standard: IEC/EN 60947-4-1
- Ambient temp: -5℃~+40℃
- Coil voltage (AC): 110V, 127V, 220V, 230V, 380V, 400V;
- Top mounting auxiliary contacts: F4-20 & F4-02 & F4-11 (2NO or 2NC or 1NO & 1NC)
- F4-13 & F4-31 (1NO & 3NC or 3NO & 1NC)
- F4-40 & F4-04 & F4-22 (4NO or 4NC or 2NO & 2NC)
- Top mounting time delay block: F5-T (making time delay); F5-D (breaking time delay)
- Assemble with Thermal overload Relay NR2 to be a DOL Starter.
- Assemble with another one to be a reversing contactor.
NR2 series thermal overload relay is used to provide overload and phase failure protection for AC motors.
- Contacts: 1N0+1NC (Electrical separated / Potential Free)
- Test / Hand & Self Reset
- Rating up to 690V, 630A. —– (11.5A, 25A, 36A, 93A, 150A, 200A, 630A)
- Standard: IEC/EN 60947-4-1
- Ambient temp: -5℃~+40℃
- NR2 Assemble with Contactor NC1, NC2, NC7 to be a DOL Starter.
CJ19 Capacitor Switching Contactor
The CJ19 Series Contactor is used in remote capacitor (130kvar) switch application.
- Rating up to 400V, 130A (AC-6b). —– (25A, 32A, 43A, 63A, 95A,115A,150A,170A)
- Standard: IEC/EN 60947-4-1
- Ambient temp: -5℃~+40℃
- Coil voltage (AC): 24V, 36V, 48V, 110V, 127V, 220V, 230V, 380V, 415V, 440V, 480V, 500V
- CJ19-25: Rating current 17A (AC-6b/380V);
- Power of controlled capacitor≤12.5kvar.
- CJ19-32: Rating current 23A (AC-6b/380V);
- Power of controlled capacitor≤20kvar.
- CJ19-43: Rating current 29A (AC-6b/380V);
- Power of controlled capacitor≤25kvar.
- CJ19-63: Rating current 43A (AC-6b/380V);
- Power of controlled capacitor≤33.3kvar.
- CJ19-95: Rating current 72.2A (AC-6b/400V);
- Power of controlled capacitor≤50kvar.
- CJ19-115: Rating current 87A (AC-6b/400V);
- Power of controlled capacitor≤60kvar.
- CJ19-150: Rating current 115A (AC-6b/400V);
- Power of controlled capacitor≤80kvar.
- CJ19-170: Rating current 130A (AC-6b/400V);
- Power of controlled capacitor≤90kvar

NXC AC Contactor and Overload Relay



The NXC series AC contactor is used in remote motor (≤335kW) control application.
- Rating up to 690V, 630A (AC-3). ——(6A, 9A, 12A, 16A, 18A, 22A, 25A, 32A, 38A, 40A, 50A, 65A, 75A, 85, 100A, 120A, 160A, 185A, 225A, 265A, 330A, 400A, 500A, 630A)
- Standard: IEC/EN 60947-4-1
- Ambient temp.: -35℃~+70℃
- Coil voltage 6A~12A (mini type): 24V, 36V, 48V, 110V, 127V, 220V, 380V, 415V (AC)
- Coil voltage AC : 6A~225A: 24V, 36V, 48V, 110V, 127V, 220V, 380V, 415V (AC)
- Coil voltage AC/DC : 265A~630A: 24V, 36V, 48V, 110V, 127V, 220V, 380V, 415V (AC/DC)
- Coil voltage DC: 24V, 48V, 110V, 220V (DC)
- Side mounting and Top Mounted auxiliary contacts
- Top mounting time delay block: F5-T (making time delay) & F5-D (breaking time delay)
- Assemble with Thermal Overload Relay NXR to be a DOL Starter.
- Assemble with another one to be a reversing contactor.
The NXR series thermal overload relay is used to provide overload and phase failure protection for AC Motors
- Rating up to 690V, 630A (AC-3): —— (12A for mini type, 25A, 38A, 100A, 200A, 630A)
- NXR-200 and NXR-630 are electronic overload relay.
- Standard: IEC/EN 60947-5-1
- Ambient temp.: -35℃~+70℃
MPCB
- Rated Operational Voltage: 230V,415V,690VAC
- Type NS25- Push Button and Type NS25X- Rotary Knob
- Current Rating: (0.1-0.16A) to (20-25A)
- NS280B –(16-25A) to (56-80A)
- Accessories: Front or Side Aux Contacts
- Fault signalling Contact, UVR,Shunt
- Certification: CE / UL
- Standard: IEC/EN-60947-2

NJYB3 Relay

For example, it is used for power control systems, air conditioning systems and motors.
NJS5 Time Delay Relay
Indication of operational states with LEDs. DIN rail mounting and compact 18 mm design.

NJBK2 Motor Protection Relay

NJBK7 Motor Protection Relay
- Standard: IEC 60947-4-1
- Rating current: 1A~800A, Rogowski coil is applied for high curren.t
- Rating control voltage: 50Hz AC220V, AC230V, AC240V, AC380V, AC400V, AC415V.
- Trip class: 5, 10A, 10, 20, 30.
- Various motor protection functions, with RS485 interface and 4mA-20mA analog transmission interface for communication and monitor.
- With LED display and setting button, smaller size can save installation space.
- Can operate for auto-coupling or star-delta start.57


NJX-13FW - Miniature Power Relay & Relay Base/Socket

JMK-2P - Miniature Power Relay & Relay Base/Socket


Type “eBG” (6KA/B,C Curve)


Function
- Protection of circuits against short-circuit currents, protection of circuits against overload currents switch & isolation
Selection
- Technical data of the network at the point considered: the earthing the earthling system (TNS, TNC), short-circuit current at the circuit at the circuit-breaker installation point which must always be less than the breaking capacity of this device, network normal voltage.
Tripping Curves:
- B-curve (3-5In) protection for people and big length cables in TN and IT systems.
- C-curve (5-10In) protection for resistive and inductive loads with low inrush current
MCB Features:
- Range available from 1A to 40A
- Single pole to Four pole – C curve
- Rated voltage: 230/400~240/415
- Rated breaking capacity: 6kA
- Confirm to IEC 60898-1 & IEC 60947-1(8-12 In) / ISI Marking
MCB Type NB1-63H (10KA/ B, C, D Curve)
Function
- Protection of circuits against short-circuit currents, protection of circuits against overload currents switch & isolation
Selection
- Technical data of the network at the point considered: the earthing the earthling system (TNS, TNC), short-circuit current at the circuit at the circuit-breaker installation point which must always be less than the breaking capacity of this device, network normal voltage.
Tripping Curves:
- B-curve (3-5In)
- C curve (5-10In)
- D curve (10-14In)
MCB Features:
- Range available from 1A to 40A
- Single pole to Four pole – C curve
- Rated voltage: 230/400~240/415
- Rated breaking capacity: 6kA
- Confirm to IEC 60898-1 & IEC 60947-1(8-12 In) / ISI Marking




MCB Type NB1-63DC for Photovoltaic (Solar System)

- Ambient temp.: -35℃~+70℃
- Range 1A to 63A
- Pole: 1P, 2P, 4P
- Tripping curves: C curve (7-10In)
- Breaking Capacity :6KA

RCCB

- Sensitivity: 10 mA,30mA,100mA,300mA @ 6KA/10KA
- Current Rating: 16A,25A,32A,40A,63A
- Pole: 2P,4P
- Type A and AC
NM1B Series MCCB

- Standard: IEC 60947-2。
- Application: Power Distribution
- Insulation Voltage :800VAC
- Pole: 1P,3P MCCB
- Range 10A to 125A @ 415V (3P), 230V / 240V (1P),50Hz
- Breaking Capacity: 10KA
- Release: Fixed Thermal Magnetic
NM1 - Series MCCB
Circuit breakers and auxiliaries comply with the international standard:
- IEC/EN 60947-1: general rules
- IEC/EN 60947-2: circuit breakers
- Application: Power Distribution and Motor Protection
- Rated current from 10 to 1250A @ 690VAC,50/60Hz
- Release: fixed thermal and fixed magnetic trip.
- Complete range of one, two, three and four-pole version
- Breaking capacity (Icu) : 15KA,20KA,25KA,35KA,50KA,65KA, 70kA
- Vertical/horizontal installation
- A complete system of add-on modules for NM1
- Operation: Manual / Rotary Handle / Motorised.

NXM / NXMS Series MCCB

- Standards: IEC/EN 60947-1, 60947-2
- -35℃~+70℃ operating temperature range
- Certification: CB, CE, KEMA
- NXM Frame current: 63/125/160/250/400/630/800/
- 1000/1250/1600A (Fixed TM Release)
- NXMS: Adjustable Electronic MCCB
- Rated voltage: 220/230/240;380/400/415V
- Operational Voltage 690VAC
- Breaking capacity: 20KA,25KA,35KA 50KA/70KA
- With Complete accessories
- Modbus Communication Module –COMA-3 for NXMS MCCB.
- Installation method: Fixed type; plug-in type
- Dual insulation design
NM8N Series Moulded Case Circuit Breaker (For Global Market)
- Ambient temperature: -40℃ ~+70℃
- Rated insulation voltage: 1000V
- Frame Size current: 125, 250, 400, 630, 800, 1600A
- Poles: 1P 2P 3P 4P
- AC MCCB: Rated Voltage Ue(V): AC 380/400/415, 440, 500, 660/690V
- DC MCCB:
- DC250V 1P / DC500V 2P in series
- DC750V 3P in series / DC1000V 4P in series
- Rated ultimate short-circuit breaking current(kA): 36, 50, 75, 100, 150KA
- Rated service breaking current(kA): Ics = 100%Icu
- Utilization category: A (Thermal-magnetic) B (Electronic)
- Release units Type:
- Thermal magnetic (TM), Magnetic (M), Electronic-LCD Display (EN&EM), Electronic type for motor protection (ENM&EMM)
- Standard complied: IEC/EN 60947-2

DZ 158 Series DIN Rail- MCCB (Higher Rating MCB)

- Protection of circuits against short-circuit & overload
- Rated current In :63A, 80A, 100A, 125A
- Poles :1P, 2P, 3P, 4P
- Rated voltage Ue :230/400~240/415 Volts
- Rated breaking capacity: 6/10 kA
- Confirm to IEC60947-2
NHR40 Fuse-Switch Disconnector

- Rated current: 160~630A.
- AC Rated voltage AC690V,50Hz Duty: AC22/AC23
- DC: DC440V and below
- NHR40 series are infrequently manually operated multipolar fuse combination switches,
- NHR40 break or switch off on load and provide safely isolation and protection against overcurrent for any voltage electrical circuit.
- Standard: IEC/EN 60947-3.
HH15-QSA Fuse-Switch Disconnector
- Rated current: 63~630A
- Duty : AC22
- Rated voltage AC690V,50Hz Duty
- Standard: IEC/EN 60947-3.

NHR17 Fuse-Switch Disconnector

NHR17 FSD series fuse-swith disconnector is a new product developed by our company.
- Rated insulation voltage up to 800V.
- Rated operational voltage up to 690V@50Hz
- Current 32A to 630A
In the distribution circuit and motor circuit which has high short-circuit current as the power switch, isolating switch,
Emergency switch as well as circuit protection,but normally it is not used to make and break a single motor directly.
- Standard: IEC/EN 60947-3.
NHRT40 Vertical Fuse-Switch Disconnector
- Standard: IEC/EN 60947-3.
- Rated current: 160~630A.
- They break or switch off on load and provide safely isolation and protection against overcurrent for any voltage electrical circuit.

NH40 Fuse-Switch Disconnector

Application
- NH40 series Switch-disconnector is applicable for AC 50Hz, rated voltage AC 690V and below,
- DC440V and below, rated current up to 3150A.
In the industrial enterprise power distribution equipment,it can be used to connect and disconnect the circuit and isolate the power supply frequently, especially the 125A~630A can be used as frequent connected and broken.
- Standard: IEC/EN60947-3.
Knife Contact Fuses
- Rated current range: 4A ~ 1250A ,50Hz
- Rated voltage: to AC690V
- Rated breaking capacity:120kA
- Category: gG type
- Open structure, good heat dissipation condition
- Mainly used for electrical circuit overload and short circuit protection
- Standards compliant: GB/T 13539.2, IEC60269-2

Cylindrical Fuses & Base


Cylindrical Fuses & Base(For Solar)

Control Fuses, Cylindrical BS Type)
- Rated current range: 2A-32A ~ 63A
- Rated breaking capacity: 100kA
- Rated voltage: to AC500V
- Standards compliant: GB/T 13539.2, IEC60269-2
- Category: gG type
- Patented appearance, modular design, practical and good-looking
- Rail mounting, easy and fast
- Mainly used for electrical circuit overload and short circuit protection
Note: this type of fuse is not recommended for capacitor cabinet
NXZM Series ATS (CB Type)

NXZM Series Automatic Transfer Switching Equipment is applicable to three-phase four-wire duplicate supply grid of AC 50/60Hz, rated voltage 400V/415V and below, rated current 800A, and can switch one or several load circuits from one power source to the other to ensure the normal power supply of the load circuit.
This product is applicable to industrial and commercial power use places, high-rise buildings, and residential houses.
Standard:IEC 60947-1, IEC 60947-6-1.
NXA Air Circuit Breaker

- Real Time Temperature Sensor (Optional)
- Continuous function monitoring
- More accurate risk identification
- Frame size(A): 1600,2000,3200,4000
- Breaking capacity: 42KA,50KA,55KA,80KA,100KA
- Rated operational voltage Ue(VAC): 380/400/415
- Number of poles: 3P,4P
- Installation method: draw-out type, fixed type
- Wiring type: horizontal rear connection
- Ambient Temperature: -5℃-+40℃…. Also operate at Temperature -35℃-+70℃
- Protection grade: Front IP 20, other side IP 00
- Intelligent Controller / Microprocessor Release
- M Type (Basic) LSIG
- A Type: M type LSIG + Current Measurement with display
- Current Unbalance Protection
- P Type (Power)
- H Type (Harmonics) with Communication.
Starter

NQ3 Series DOL Electromagnetic Starter
- Range 3KW / 5.5KW/11KW
- Current Range : 17-25A
- AC660VAC @50/60Hz
- Coil Voltage: 380VAC,220VAC,415VAC
NQ 2 DOL Starter
- Motor KW Range: Up to 33KW
- Current: Up to 68Amps
- AC660VAC @50/60Hz
- Coil Voltage: 380VAC,220VAC,415VAC
- To start/Stop/Protect the motor from overload & single phase.
NVF2G VFD
Application
- Fan and Pumps
- General Purpose
- Input Voltage: 380Volt – 400Volt
- Input Frequency: 47-63 Hz
- Frequency Output Voltage- 0V torated input Voltage
- Output Frequency for Fan & Pump:-0-120 Hz
- Output Frequency for General Type-0-400 Hz
- Confirm to IEC 61800-2

Limit Switch & Travel Switch





- YBLX-ME Travel Switch
- YBLX-WL Travel Switch
- YBLX-CK Travel Switch
- YBLX-P1 Travel Switch
- YBLX-K3 Travel Switch
- YBLX-19 Travel Switch
- YBLX-K1 Travel Switch
LED Indicators
ND 16 – Round Shape LED Lamps 22.5mm (Resistive Type)
Suitable for AC/DC Voltage
- Voltage: 230V/240V (Standard Control Panel Voltage)
- Voltage: 6V,12V AC/DC (Solar System)
- Voltage: 24V,48V,110V,380V AC/DC (Automation Panel)
- Colour: Red, Yellow, Green, Amber(Orange)
- Colour: Blue / White



Push Buttons


- Contact; 1N0,1NC,1N0+1NC,2N0,2NC
- Color : Black,Red,Yellow,Blue,Green
- Illuminated / Non Illuminated
- Push Buttons / Selector Switch / Maintain & Movementry Mushroom PB